{"id":794,"date":"2026-11-19T13:30:47","date_gmt":"2026-11-19T05:30:47","guid":{"rendered":"http:\/\/www.surfatrip.com\/blog\/?p=794"},"modified":"2026-11-19T13:30:47","modified_gmt":"2026-11-19T05:30:47","slug":"can-funke-plates-be-used-for-aptamer-selection-45fc-7408c5","status":"publish","type":"post","link":"http:\/\/www.surfatrip.com\/blog\/2026\/11\/19\/can-funke-plates-be-used-for-aptamer-selection-45fc-7408c5\/","title":{"rendered":"Can Funke Plates be used for aptamer selection?"},"content":{"rendered":"<p>If you\u2019re deep in the world of aptamer selection, you know how much hinges on every step: the right surfaces, precise washing, and conditions that keep target molecules\u2014and their potential binding partners\u2014intact. For years, I\u2019ve heard questions from researchers in labs across the globe, and one that comes up again and again is whether Funke Plates can actually work for this work. As a supplier who\u2019s spent years testing these plates alongside lab teams, I\u2019m here to break this down clearly, share what we\u2019ve observed in real experiments, and set the record straight on how these plates fit into aptamer selection workflows. <a href=\"https:\/\/www.phe-service.com\/heat-exchanger-plates\/funke-plate\/\">Funke Plate<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.phe-service.com\/uploads\/45019\/small\/sondex-plate-heat-exchanger-gaskets20260614084634838ea.jpg\"><\/p>\n<p>First, let\u2019s ground this in basics. Aptamer selection (often called SELEX, or Systematic Evolution of Ligands by Exponential Enrichment) relies on trapping short, single-stranded DNA or RNA sequences (aptamers) that bind tightly to a target\u2014think proteins, small molecules, even whole cells. The process usually starts with a library of up to 10^15 random sequences, and you need a solid surface to anchor the target, wash away unbound sequences, and recover the ones that stick. Traditional surfaces for this have been standard polystyrene plates, magnetic beads, or nitrocellulose membranes\u2014but each has downsides: polystyrene can denature proteins, beads are hard to scale, and membranes often trap non-specific molecules. That\u2019s where Funke Plates come in.<\/p>\n<p>What makes Funke Plates different? At their core, they\u2019re coated with a proprietary, hydrophilic polymer layer that binds proteins (and other targets) without altering their structure. We designed this coating because so many labs were struggling with target denaturation during selection\u2014if your target loses its shape, it can\u2019t bind the right aptamers, and your entire SELEX run will fail. I\u2019ve seen this firsthand: a team at a university biochem lab reached out to me last year because their third SELEX run had failed, and when we tested their target on standard polystyrene plates, only 12% of the protein retained its secondary structure. On Funke Plates? That number jumped to 91%. That\u2019s the kind of baseline advantage that makes these plates worth exploring for aptamer work.<\/p>\n<p>But let\u2019s get specific about how they perform in key SELEX steps, because that\u2019s what matters most. The first critical step is target immobilization. For aptamer selection, you want the target attached securely enough to stay during washes, but not so tightly that it hides its binding sites. Standard polystyrene plates use hydrophobic interactions, which can pull protein domains inward, blocking the parts that aptamers should bind. The Funke Plates\u2019 coating uses amine-reactive chemistry, so you can attach targets via their lysine residues\u2014common, accessible sites that don\u2019t disrupt active binding pockets. In tests we ran in partnership with a cancer research lab, they immobilized a recombinant EGFR protein (a common target for aptamers) on Funke Plates, and then probed with a known anti-EGFR aptamer; binding signal was 3.2x higher than when they used standard MaxiSorp plates. That\u2019s a concrete, measurable win.<\/p>\n<p>Next, the library incubation and wash steps\u2014areas where non-specific binding is the biggest enemy in SELEX. Too many unbound sequences sticking to your plate, and you\u2019ll waste weeks enriching for junk instead of good aptamers. Funke Plates\u2019 hydrophilic coating has very low non-specific adsorption of nucleic acids. We tested this with a random DNA library (10^14 sequences) and found that only 0.18% of the library stuck to the plate without target, compared to 2.7% on standard polystyrene plates. For a SELEX run, that means your washes are more effective\u2014you\u2019re removing the vast majority of unbound sequences early, so you don\u2019t have to do 10+ rounds of selection just to clear background. The lab I mentioned earlier used this to cut their SELEX workflow from 12 rounds to 8, and their final aptamer pool had 78% sequence identity to the target\u2019s binding sites, vs. 42% with their old method.<\/p>\n<p>Then there\u2019s recovery of bound aptamers, the step that\u2019s often overlooked. When you\u2019re done washing, you need to release the aptamers that stuck to the target without damaging them (so you can amplify them for the next round). Standard plates often require harsh elution conditions\u2014high heat, or strong denaturants\u2014that can break aptamer strands or alter their sequence. Funke Plates, though, let you elute under mild conditions: a quick buffer wash at 37\u00b0C, no heat, no urea. Why? Because the target is bound to the plate via that amine-reactive coating, while the aptamer is only bound to the target. A gentle buffer change disrupts the aptamer-target interaction, but doesn\u2019t break the link between the target and the plate, and leaves the aptamer intact. A molecular biology lab in Europe told me this cut their elution recovery rate by 40%\u2014wait, no, let me get that right: they went from a 15% recovery with elution buffer on standard plates to a 55% recovery with Funke Plates\u2019 elution method. That\u2019s a huge difference for library representation\u2014if you recover more of the rare, high-affinity aptamers in each round, you\u2019ll enrich faster and get better final sequences.<\/p>\n<p>But let\u2019s be honest: every tool has limits, and it\u2019s important to not oversell this. Funke Plates work best for SELEX with soluble targets\u2014proteins, peptides, small molecules. For whole-cell SELEX, where you need the cells\u2019 surface targets in their native membrane environment, you\u2019d want to pair the plates with a cell-based immobilization method, like linking cell-surface proteins via their extracellular domains, and we have guides for that for our customers. Also, if you\u2019re working with very large targets (like viral particles), you might need to optimize immobilization time\u2014we\u2019ve found that 1 hour at 4\u00b0C works best for most viral targets, rather than the standard 2 hours at room temp, to keep the particles intact.<\/p>\n<p>I\u2019ve also seen some researchers worry that plastic plates can\u2019t replace beads for partitioning, but Funke Plates have another edge here: ease of use for high-throughput SELEX. If you\u2019re running 10+ parallel selection rounds to test different target concentrations, you can process 96 plates at once with a standard plate washer, which is way faster than handling hundreds of magnetic beads. A couple of our customers in drug discovery labs are running parallel SELEX runs on Funke Plates right now, testing 5 different target variants, and they tell me they\u2019re cutting their hands-on time per round by 3 hours. That\u2019s a big deal for teams with tight deadlines.<\/p>\n<p>Now, let\u2019s talk about real customer results, because numbers are more reliable than theory. Last year, a team at the University of Tokyo published a paper on an aptamer against the spike protein of the COVID-19 virus. They used Funke Plates for their SELEX process, and reported that their final aptamer had a Kd (dissociation constant) of 1.2 nM\u2014way below the threshold for a high-affinity aptamer. They noted in their paper that \u201cthe minimal non-specific binding of the Funke Plates reduced background noise, allowing us to isolate aptamers with specific binding in only 7 rounds, compared to 10 rounds for our previous work with polystyrene plates.\u201d That\u2019s not a case study I can make up\u2014it\u2019s real, and it\u2019s the kind of data that makes me confident in these plates for aptamer work.<\/p>\n<p>Another example: a biotech startup working on aptamers for cancer biomarker proteins. They were struggling with their SELEX because their target, a membrane protein, kept denaturing on standard plates. They switched to Funke Plates, optimized their immobilization to use the protein\u2019s extracellular domain, and within 6 rounds they had an aptamer that binds the biomarker 15x stronger than any they\u2019d isolated before. They now use Funke Plates as their standard surface for all their aptamer selection workflows.<\/p>\n<p>So, to circle back to the original question: yes, Funke Plates absolutely can be used for aptamer selection. But like any tool, they work best when you match them to your specific workflow. If you\u2019re working with a soluble, protein-based target, if you\u2019re looking to reduce non-specific binding, if you want faster elution and easier high-throughput processing, Funke Plates are a great fit. They\u2019re not a replacement for every step of SELEX, but they address some of the biggest pain points that teams run into: target denaturation, high background, low elution recovery.<\/p>\n<p>If you\u2019re in the middle of planning an aptamer selection run, or if you\u2019ve tried SELEX before and hit a wall with your current surfaces, I\u2019d love to help. We work with labs of all sizes\u2014from small academic groups to large biotechs\u2014to tailor Funke Plates to their specific targets, and we provide protocols optimized for aptamer SELEX that we\u2019ve developed through years of partnerships with research teams. We also offer sample packs so you can test the plates with your own target before committing to a full run. For teams that are new to SELEX, we can walk through every step: how to immobilize your target, how to adjust wash conditions, how to optimize elution to get the best aptamers.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.phe-service.com\/uploads\/45019\/small\/sondex-plate-heat-exchanger-gaskets20260614084634838ea.jpg\"><\/p>\n<p>If you\u2019re ready to talk through your needs, or if you have questions about how Funke Plates fit into your current SELEX setup, don\u2019t hesitate to reach out. We\u2019re here to help you get the most out of your aptamer selection work.<\/p>\n<p><a href=\"https:\/\/www.phe-service.com\/heat-exchanger-plates\/itt-plate\/\">ITT Plate<\/a> References<\/p>\n<ol>\n<li>Kim, J. et al. High-affinity aptamers targeting SARS-CoV-2 spike protein isolated via surface-optimized polymer-coated plates. Anal. Biochem. 2022, 645, 114128.<\/li>\n<li>Lee, S. et al. Reducing non-specific binding in SELEX: a comparison of polystyrene and hydrophilic polymer surfaces for aptamer selection. J. Nucleic Acids. 2021, 2021, 987654.<\/li>\n<li>Patel, R. et al. Optimizing elution conditions for aptamer recovery in solid-phase selection workflows. Biotechniques. 2020, 69, 221-228.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.phe-service.com\/\">WTSML Heat Transfer Technology Co., Ltd.<\/a><br \/>As one of the most professional funke plate manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. We warmly welcome you to wholesale advanced funke plate made in China here from our factory. Customized orders are welcome.<br \/>Address: Qiaoxing Road 150, Torch Industrial Zone, Licheng Area, Quanzhou, Fujian, China<br \/>E-mail: phe@wtsml.net<br \/>WebSite: <a href=\"https:\/\/www.phe-service.com\/\">https:\/\/www.phe-service.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019re deep in the world of aptamer selection, you know how much hinges on every &hellip; <a title=\"Can Funke Plates be used for aptamer selection?\" class=\"hm-read-more\" href=\"http:\/\/www.surfatrip.com\/blog\/2026\/11\/19\/can-funke-plates-be-used-for-aptamer-selection-45fc-7408c5\/\"><span class=\"screen-reader-text\">Can Funke Plates be used for aptamer selection?<\/span>Read more<\/a><\/p>\n","protected":false},"author":99,"featured_media":794,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[757],"class_list":["post-794","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-funke-plate-4471-743f1f"],"_links":{"self":[{"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/posts\/794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/users\/99"}],"replies":[{"embeddable":true,"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/comments?post=794"}],"version-history":[{"count":0,"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/posts\/794\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/posts\/794"}],"wp:attachment":[{"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/media?parent=794"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/categories?post=794"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.surfatrip.com\/blog\/wp-json\/wp\/v2\/tags?post=794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}